Lot
40
Manufacturer
COMBUSTION ENGINEERING / LURGI
Name
CIRCULATING, FLUIDIZED BED BOILER COMBUSTOR
Model
Serial
s/n 22985 (Mfg. 1986)
Description
With 2- Digital Instrumentation HMI Units, Emergency Relief Valve Manifold consisting of but not necessarily limited to: 4 in. (est.) Piping, insulated with Exterior Metal Jacketing, Valve with Manual Hand Wheel, 2- Safety Valves each having Steam Drums. 150,000 lbs./hr. Rated Steaming Capacity, 10,880 sq. ft. Boiler Heating Surface, 1,525 psi Max. Pressure, 950 F Superheater Inlet Temperature, 3,430 sq. ft. Water Walls, 19,100 sq. ft. Economizer. Certified by: Potts Welding & Boiler Repair Co. (2013) (s/n 03-3950-1TO18); Certified by: The Industrial Company; Repaired by Brahma Group, Inc. 12/10/11 and 3/29/13; Repaired by: Whertec Mechanical, LLC. 11/7/12; Repaired by: J.T. Thorpe & Sons, Inc. 11/20/12 and 8/30/13. With LOT 8- (approx.) SOOT BLOWERS, FIXED ROTATING TYPE: (SIMILAR TO Model G9B/IR-3D/3Z).